Parameterinterface (118)

Parent Previous Next

The parameter interface for the communication between device and PC is disturbed.

The cause of the error can be detailed by the Sub-ID:

0 - Cannot Init Parainterface: Bind failed

The initialization of the parameter interface via Ethernet failed.

1 - Cannot Init Parainterface: Listen failed

The initialization of the parameter interface via Ethernet failed.

2 - Burst-Frame too big

To many bytes are transferred on the Ethernet interface.

3 - Send-Buffer Full

The transmit buffer has overflowed.

4 - Cannot establish connection: Out of memory

The main memory is no longer sufficient to handle an incoming connection request.

5 - Parameterset Change not allowed while running

The change of parameter sets is not allowed while inverter is running.


Fehleraktion

Durch diesen Fehler wird keine Aktion ausgeführt.

Troubleshooting

The error can be acknowledged by a restart of the device.