PWM Sync Lost (116)

Parent Previous Next

The synchronization between two stacks which are operated in interleaving mode is disrupted.

The cause of the error can be detailed by the Sub-ID:

0 - Interleaving sync connection was lost

The connection through the sync line is pulled down. The slave receives no sync pulses. Check the synchronization cable and the master.

1 - Cannot set as master

The master receives pulses on the sync line. Check the configuration of the other inverter. Only one inverter has to be configured as master.



Fehleraktion

Durch diesen Fehler wird keine Aktion ausgeführt.

Troubleshooting

The error can be acknowledged by an Error-Reset.