An overcurrent was detected.
The cause of the error can be detailed by the Sub-ID:
The value of parameter 1112 was exceeded in phase U.
There are different error causes:
- on eof the motor winding has a winding circuit to another phase.
- a motor winding has a winding circuit, so that the inductance of the motor has decreased
- the supply line between inverter and motor is damaged.
- the current measurement may be damaged.
- the current measurement may have been disturbed by EMC interference.
The value of parameter 1112 was exceeded in phase V.
There are different error causes:
- on eof the motor winding has a winding circuit to another phase.
- a motor winding has a winding circuit, so that the inductance of the motor has decreased
- the supply line between inverter and motor is damaged.
- the current measurement may be damaged.
- the current measurement may have been disturbed by EMC interference.
The value of parameter 1112 was exceeded in phase W.
There are different error causes:
- on eof the motor winding has a winding circuit to another phase.
- a motor winding has a winding circuit, so that the inductance of the motor has decreased
- the supply line between inverter and motor is damaged.
- the current measurement may be damaged.
- the current measurement may have been disturbed by EMC interference.
The current sum of all three phases has exceeded the value of parameter 1140.
The cause can be a current flow in the ground line or a damaged current measurement.
Ein Not-Aus wird durchgeführt.
The error can be acknowledged by an Error-Reset. Depending on the cause of the error (see above) there may be a hardware defect which muss lead to the replacement of the modstack, motor or cable.